20:56:43.354 mon-start d2: waiting for the board to go away (warm reboot)
20:57:36.423 pre-boot operator: before class A DMM 3.8966 V/0.23 A; B9C DMM 3.991 V, USB 0.415 A; operator pressing RESET
20:57:43.425 telnet reboot sent
20:57:50.398 board gone
20:57:51.874 fastboot +5s
20:58:03.918 NCM up



DD2=00 setsid sh /tmp/b10b3-mon.sh 5 > /dev/null 2>&1 < /dev/null & sleep 1; dme
sg | grep -E "safety timer|supervisor"; cut -d" " -f1 /proc/uptime
1d2621aa3195fd3c78fd30f90da44639  /tmp/b10b3-mon.sh
[    0.925056] pm8916-lbc 200f000.spmi:pmic@0:charger@1000: safety timer 8 min (TCHG_MAX 0x01), enabled
[    0.928870] pm8916-lbc 200f000.spmi:pmic@0:charger@1000: supervisor v3: charge 4100000 uV, hold 4000000 uV, full-min 4050000 uV, cv 5 min, IBAT_MAX code 4, ovp 4250000 uV
[    0.959747] pm8916-lbc 200f000.spmi:pmic@0:charger@1000: supervisor INIT -> CHARGING (probe, usb present), vbat 3929739 uV
14.96
[1]+  Done                       setsid sh /tmp/b10b3-mon.sh 5 1>/dev/null 2>&1 0</dev/null
20:58:11.946 local md5 1d2621aa3195fd3c78fd30f90da44639  -
20:58:11.948 monitor started (5 s), pull started -> logs/b10/b10b3/d2-mon.txt
21:00:11 Test D run 2 (branch 2): v3 entered CHARGING at VBAT 3.930 V but CHGR RT 01 + path 01 in every sample (no FAST_CHG_ON) -> timer test stopped as non-informative; monitor stopped, end dump; board left CHARGING on the Test D image