// SPDX-License-Identifier: GPL-2.0-only /* * Project Aurora - B10B-3 Test D: TEST-ONLY DTB (safety timer expiry during CHARGING, battery at ~4.0 V). Never for persistent use. * = Test C DTB (charge 4.10 V -> VDD_MAX 0x04, HOLD 4.00 V, full-min 4.05 V, CV 5 min, IBAT_MAX 450 mA) + safety timer 8 min (TCHG_MAX 0x01), * so the timer expires in CC, long before the CV/HOLD criterion can be met. * Production: 4.20 V / HOLD 4.05 V / full-min 4.15 V / 60 min / 512 min (msm8916-jz08-aurora-b10b3.dts). */ #include "msm8916-jz08-aurora-b10b3.dts" / { model = "JZ08AU Aurora (RAM boot B10B-3 Test D)"; }; &battery { voltage-max-design-microvolt = <4100000>; }; &pm8916_charger { qcom,charge-timeout-minutes = <8>; aurora,hold-voltage-microvolt = <4000000>; aurora,full-min-voltage-microvolt = <4050000>; aurora,cv-hold-minutes = <5>; };