12:38:34 T1 step1: test_recharge_uv=3000000 (safe low), force_terminate $D/force_terminate; head -3 $D/state; grep -E "CHG_CTRL|CHG_STATUS|USB_PATH" $D /state; tail -2 $D/state state TERMINATED fault none vbat_uv 3905550 recharge_uv 3000000 (production 4050000, test 3000000) done_polls 0 low_polls 0 timeout_min 512 n_terminated 0 n_recharge 0 n_forced 1 CHG_STATUS 05 CHG_CTRL 21 USB_PATH 01 log 0 t=0 INIT->CHARGING vbat=3810027 probe, usb present log 1 t=91 CHARGING->TERMINATED vbat=3905550 FORCED by test hook ltage6_input); echo v=$v; s=$((s+v)); sleep 2; done; echo AVG=$((s/6)); grep -E "CHG_STATUS|USB_PATH|CHG_CTRL" /sys/kernel/debug/pm8916_lbc/state v=3913632 v=3894006 v=3898335 v=3914208 v=3894006 v=3913920 AVG=3904684 CHG_STATUS 05 CHG_CTRL 21 USB_PATH 01 12:41:20 T1 PAUSED/ABORTED: operator meter 0.358 A with CHG_CTRL=21 (CHG_EN=0, FORCE_BATT_ON=1), CHG_STATUS 05, USB_PATH 01, VBAT not falling -> disable via CHG_CTRL does not stop the charger; no further writes 12:45:08 B10B-3 ram1 STOPPED by operator decision; monitor+pull stopped; awaiting class-A reset