q 58dcb3d121 B10: battery charging — PM8916 LBC supervisor v4 (CHARGE/HOLD, FAULT safe clamp to 4.00 V) and persistent B10B-5 cache
- LBC supervisor v1..v4 (linux/patches/b10b3-lbc-supervisor-v3.patch + b10/b10b3/lbc-v3-to-v4-fault-clamp.diff):
  CHARGING 4.20 V/450 mA -> HOLD 4.05 V after 60 min CV -> battery -> new cycle on USB insert; FAULT = VDD_MAX 4.00 V clamp
- RAM tests C/B/D/D2/D3/D4 (safety timer only ends fast charge), B10B-4 actuator audit (VDD_MAX works, USB_SUSP does not),
  B10B-5 FAULT clamp regression, production run, warm reboot via PON reboot reason
- cache = B10B-5 c3732515 (HW EDL write, readback + full partition verify), class-A persistent validation
- test-only hooks/images are not part of the production kernel; images with the AP PSK are not published
2026-10-04 19:00:27 +03:00

19 lines
872 B
Text

// SPDX-License-Identifier: GPL-2.0-only
/*
* Project Aurora - B10B-3T: TEST-ONLY DTB for the accelerated RAM test of the recharge supervisor.
* Never used for persistent integration. Differs from the production B10B-3 DTB only in the battery limits:
* voltage-max-design 4.00 V -> pm8916_lbc programs VDD_MAX = 0x00 (4000 mV, the lowest LBC step; 3.95 V is not
* supported: VDD_MAX = 4000 + 25 mV x n) so a battery at ~3.9 V reaches real CV and hardware end of charge quickly;
* re-charge-voltage-microvolt 3.94 V (test recharge threshold, 60 mV below the test float).
* Production stays 4.20 V / 4.05 V / 450 mA / 512 min (msm8916-jz08-aurora-b10b3.dts).
*/
#include "msm8916-jz08-aurora-b10b3.dts"
/ {
model = "JZ08AU Aurora (RAM boot B10B-3T TEST)";
};
&battery {
voltage-max-design-microvolt = <4000000>;
re-charge-voltage-microvolt = <3940000>;
};