- LBC supervisor v1..v4 (linux/patches/b10b3-lbc-supervisor-v3.patch + b10/b10b3/lbc-v3-to-v4-fault-clamp.diff): CHARGING 4.20 V/450 mA -> HOLD 4.05 V after 60 min CV -> battery -> new cycle on USB insert; FAULT = VDD_MAX 4.00 V clamp - RAM tests C/B/D/D2/D3/D4 (safety timer only ends fast charge), B10B-4 actuator audit (VDD_MAX works, USB_SUSP does not), B10B-5 FAULT clamp regression, production run, warm reboot via PON reboot reason - cache = B10B-5 c3732515 (HW EDL write, readback + full partition verify), class-A persistent validation - test-only hooks/images are not part of the production kernel; images with the AP PSK are not published
27 lines
1.7 KiB
Text
27 lines
1.7 KiB
Text
== PMIC diff vs baseline (B10B-0 boot)
|
||
3100 (1): 3160:a1>a3
|
||
3200 (1): 3260:69>61
|
||
3300 (1): 3360:47>2b
|
||
4000 (19): 4009:53>22 4011:00>10 4015:00>10 4016:00>10 4047:55>22 4056:07>0a 4060:b2>68 4061:9a>36 4062:01>04 4066:08>15 406a:95>7a 40c0:7d>5f 40c2:7e>65 40c4:7b>ff 40c5:33>ff 40c6:7e>ff 40c7:33>ff 40c8:7e>ff 40c9:33>ff
|
||
6000 (2): 6048:68>ae 6049:02>01
|
||
BMS config: 4040 0a>0a 4046 80>80 4047 55>22 4055 0a>0a 4056 07>0a
|
||
charger: CHG_CTRL 90>90 VDD_MAX 08>08 VDD_SAFE 08>08 IBAT_MAX 00>00 IBAT_SAFE 0a>0a VIN_MIN 04>04 IBATTERM(term) 09>09 TCHG_EN 80>80 TCHG 1d>1d COMP_OVR1 00>00 USB_PTH_STS 90>90 USB 0x1308 02>02 BOOT_DONE 80>80
|
||
|
||
n VBAT_vadc BMS_now FIFO0 FIFO1 FIFO1x284.3 VPH
|
||
1 3.7451 3.9486 13135 13162 3.7420 3.7477
|
||
2 3.7396 3.9486 13135 13162 3.7420 3.7465
|
||
3 3.7465 3.9486 13158 13162 3.7420 3.7483
|
||
4 3.7474 3.9495 13158 13165 3.7428 3.7491
|
||
5 3.7468 3.9495 13164 13165 3.7428 3.7480
|
||
6 3.7309 3.9495 13164 13165 3.7428 3.7477
|
||
7 3.7451 3.9486 13164 13162 3.7420 3.7480
|
||
8 3.7445 3.9486 13162 13162 3.7420 3.7468
|
||
9 3.7454 3.9483 13162 13161 3.7417 3.7312
|
||
10 3.7434 3.9483 13162 13161 3.7417 3.7460
|
||
11 3.7436 3.9483 13145 13161 3.7417 3.7457
|
||
12 3.7442 3.9444 13145 13148 3.7380 3.7471
|
||
VADC mean 3.7436 (σ 4.5 mV); BMS-VM mean 3.9484 (σ 1.3 mV)
|
||
BMS-VM - VADC = +204.8 mV (+5.47 %)
|
||
FIFO coeff this run: 284.4 uV/LSB (VADC/FIFO1); upstream 300 -> error +5.47 %; B10B-0 value 284.3
|
||
BMS-VM corrected (x284.4/300): mean 3.7436 -> diff vs VADC +0.0 mV
|
||
OCV raw reg 12922 -> x300 3.8766 V (driver probe value 3.8766), x284.4 3.6755 V
|