uzbek-plus/logs/b10/b10b3/b1-actions.txt
q 58dcb3d121 B10: battery charging — PM8916 LBC supervisor v4 (CHARGE/HOLD, FAULT safe clamp to 4.00 V) and persistent B10B-5 cache
- LBC supervisor v1..v4 (linux/patches/b10b3-lbc-supervisor-v3.patch + b10/b10b3/lbc-v3-to-v4-fault-clamp.diff):
  CHARGING 4.20 V/450 mA -> HOLD 4.05 V after 60 min CV -> battery -> new cycle on USB insert; FAULT = VDD_MAX 4.00 V clamp
- RAM tests C/B/D/D2/D3/D4 (safety timer only ends fast charge), B10B-4 actuator audit (VDD_MAX works, USB_SUSP does not),
  B10B-5 FAULT clamp regression, production run, warm reboot via PON reboot reason
- cache = B10B-5 c3732515 (HW EDL write, readback + full partition verify), class-A persistent validation
- test-only hooks/images are not part of the production kernel; images with the AP PSK are not published
2026-10-04 19:00:27 +03:00

24 lines
1.5 KiB
Text

17:33:38.893 mon-start b1: waiting for the board to go away (warm reboot)
17:34:46.116 pre-boot operator: DMM VBAT 4.113 V, USB meter 0.424 A (B9C, SBL charge); RESET held
17:34:51.118 telnet reboot sent (RESET held)
17:35:02.044 board gone
17:35:17.064 NCM up
DD2=00 setsid sh /tmp/b10b3-mon.sh 10 > /dev/null 2>&1 < /dev/null & sleep 1; dm
esg | grep -E "safety timer|supervisor"; cut -d" " -f1 /proc/uptime
1d2621aa3195fd3c78fd30f90da44639 /tmp/b10b3-mon.sh
[ 0.929300] pm8916-lbc 200f000.spmi:pmic@0:charger@1000: safety timer 8 min (TCHG_MAX 0x01), enabled
[ 0.933414] pm8916-lbc 200f000.spmi:pmic@0:charger@1000: supervisor v3: charge 4050000 uV, hold 4000000 uV, full-min 4030000 uV, cv 2 min, IBAT_MAX code 4, ovp 4250000 uV
[ 0.963800] pm8916-lbc 200f000.spmi:pmic@0:charger@1000: supervisor INIT -> CHARGING (probe, usb present), vbat 3972945 uV
16.40
[1]+ Done setsid sh /tmp/b10b3-mon.sh 10 1>/dev/null 2>&1 0</dev/null
17:35:25.087 local md5 1d2621aa3195fd3c78fd30f90da44639 -
17:35:25.088 monitor started (10 s), pull started -> logs/b10/b10b3/b1-mon.txt
17:55:04 operator: DMM VBAT 4.014 V, USB meter 0.000 A
17:56:04 operator: USB meter briefly 0.01 A (1 s), otherwise 0.000 A
17:57:20 load start: 2x yes, guard PMIC>52C / VBAT<3.95V / 300 s (operator request)
17:58:01 operator: under 2x load USB meter 0.08-0.10 A peak
18:04:36 operator: idle after load DMM VBAT 4.002 V, USB meter 0.017 A
18:05:28 Test B END: monitor stopped, final dump taken, pull stopped; board left in HOLD (Test B RAM image)