- LBC supervisor v1..v4 (linux/patches/b10b3-lbc-supervisor-v3.patch + b10/b10b3/lbc-v3-to-v4-fault-clamp.diff): CHARGING 4.20 V/450 mA -> HOLD 4.05 V after 60 min CV -> battery -> new cycle on USB insert; FAULT = VDD_MAX 4.00 V clamp - RAM tests C/B/D/D2/D3/D4 (safety timer only ends fast charge), B10B-4 actuator audit (VDD_MAX works, USB_SUSP does not), B10B-5 FAULT clamp regression, production run, warm reboot via PON reboot reason - cache = B10B-5 c3732515 (HW EDL write, readback + full partition verify), class-A persistent validation - test-only hooks/images are not part of the production kernel; images with the AP PSK are not published
25 lines
1.6 KiB
Text
25 lines
1.6 KiB
Text
14:45:41.807 mon-start b5r2: waiting for lk1st fastboot (RESET-held reboot), then for the new boot
|
|
14:47:21.206 pre-boot operator: USB 0.000 A (B9C, likely 00/01 latch after reinsert); RESET held
|
|
14:47:26.208 telnet reboot sent
|
|
14:47:38.423 fastboot +9s
|
|
14:47:38.423 fastboot seen
|
|
14:47:41.439 fastboot gone (booting)
|
|
14:47:51.954 NCM up
|
|
|
|
|
|
|
|
DD2=02 setsid sh /tmp/b10b3-mon.sh 30 > /dev/null 2>&1 < /dev/null & sleep 1; dm
|
|
esg | grep -E "safety timer|supervisor"; cut -d" " -f1 /proc/uptime
|
|
1d2621aa3195fd3c78fd30f90da44639 /tmp/b10b3-mon.sh
|
|
[ 0.920117] pm8916-lbc 200f000.spmi:pmic@0:charger@1000: safety timer 512 min (TCHG_MAX 0x7f), enabled
|
|
[ 0.931977] pm8916-lbc 200f000.spmi:pmic@0:charger@1000: supervisor v3: charge 4200000 uV, hold 4050000 uV, full-min 4150000 uV, cv 60 min, IBAT_MAX code 4, ovp 4250000 uV
|
|
[ 0.967636] pm8916-lbc 200f000.spmi:pmic@0:charger@1000: supervisor INIT -> CHARGING (probe, usb present), vbat 4094529 uV
|
|
16.44
|
|
[1]+ Done setsid sh /tmp/b10b3-mon.sh 30 1>/dev/null 2>&1 0</dev/null
|
|
14:47:59.977 local md5 1d2621aa3195fd3c78fd30f90da44639 -
|
|
14:47:59.978 monitor started (30 s), pull started -> logs/b10/b10b3/b5r2-mon.txt
|
|
14:57:46 operator: USB off (DMM 4.138 V) >=10 s, USB ON, meter 0.25 A
|
|
14:58:25 FAULT injection (ovp) start
|
|
15:01:52 FAULT clamp operator meter: 0.010 A at +5 s, 0.000 A at +60 s (before: 0.25 A)
|
|
15:03:27 FAULT exit: operator USB off (DMM 4.125 V) >=10 s, USB ON, meter 0.36 A
|
|
15:04:09 B10B-5 RAM regression END: PASS; FAULT exit -> CHARGING VDD 08 FAST; monitor stopped; board left CHARGING on the TEST image
|