- LBC supervisor v1..v4 (linux/patches/b10b3-lbc-supervisor-v3.patch + b10/b10b3/lbc-v3-to-v4-fault-clamp.diff): CHARGING 4.20 V/450 mA -> HOLD 4.05 V after 60 min CV -> battery -> new cycle on USB insert; FAULT = VDD_MAX 4.00 V clamp - RAM tests C/B/D/D2/D3/D4 (safety timer only ends fast charge), B10B-4 actuator audit (VDD_MAX works, USB_SUSP does not), B10B-5 FAULT clamp regression, production run, warm reboot via PON reboot reason - cache = B10B-5 c3732515 (HW EDL write, readback + full partition verify), class-A persistent validation - test-only hooks/images are not part of the production kernel; images with the AP PSK are not published
27 lines
2.1 KiB
Text
27 lines
2.1 KiB
Text
01:30:20 note: first mon-start misfired on a single lost ping (pushed monitor to B9C, stopped); starter now waits for fastboot instead
|
|
01:30:20.452 mon-start p1: waiting for lk1st fastboot (RESET-held reboot), then for the new boot
|
|
01:31:06.462 pre-boot operator: DMM 4.074 V (B9C), USB 0.41 A; RESET held
|
|
01:31:11.464 telnet reboot sent
|
|
01:31:45.605 fastboot seen
|
|
01:31:45.606 fastboot +30s
|
|
01:31:47.620 fastboot gone (booting)
|
|
01:31:56.638 NCM up
|
|
|
|
|
|
|
|
DD2=02 setsid sh /tmp/b10b3-mon.sh 30 > /dev/null 2>&1 < /dev/null & sleep 1; dm
|
|
esg | grep -E "safety timer|supervisor"; cut -d" " -f1 /proc/uptime
|
|
1d2621aa3195fd3c78fd30f90da44639 /tmp/b10b3-mon.sh
|
|
[ 0.926724] pm8916-lbc 200f000.spmi:pmic@0:charger@1000: safety timer 512 min (TCHG_MAX 0x7f), enabled
|
|
[ 0.931085] pm8916-lbc 200f000.spmi:pmic@0:charger@1000: supervisor v3: charge 4200000 uV, hold 4050000 uV, full-min 4150000 uV, cv 60 min, IBAT_MAX code 4, ovp 4250000 uV
|
|
[ 0.959935] pm8916-lbc 200f000.spmi:pmic@0:charger@1000: supervisor INIT -> CHARGING (probe, usb present), vbat 4011015 uV
|
|
15.27
|
|
[1]+ Done setsid sh /tmp/b10b3-mon.sh 30 1>/dev/null 2>&1 0</dev/null
|
|
01:32:04.662 local md5 1d2621aa3195fd3c78fd30f90da44639 -
|
|
01:32:04.663 monitor started (30 s), pull started -> logs/b10/b10b3/p1-mon.txt
|
|
03:23:47 CHARGING -> HOLD at uptime 6667.4 s (VDD_MAX 08->02), vbat 4.183 V; no FAULT/ALERT/latch
|
|
04:55:38 HOLD shelf reached: VADC VBAT ~4.05 V at t~12100 s, USBIN sag starts (5.017 -> ~5.00 V) = USB carries the board (phase 2)
|
|
11:05:12 operator on HOLD shelf: USB meter 0.1 A, DMM 4.035 V (criterion 4)
|
|
11:07:42 usbpull3 operator: DMM 4.035 V before, dip 4.009 V at pull, 4.007 V after 10 s
|
|
11:09:27 usbpull3 RESULT: heartbeat 44 beats max gap 5.02 s, no SBL/boot; HOLD->NO_USB 34513.2 s (vbat 3.891 under transient), USB back 14:08:46 local, NO_USB->CHARGING 34618.9 s (vbat 4.040): VDD_MAX 08, IBAT 04, RT 21 FAST + path 02, CHG_FAILED 00. Operator: DMM 4.003 V before replug, 4.10 V after, USB 0.4 A; display and Wi-Fi worked the whole time
|
|
11:13:56 production run interrupted for software warm-reboot feasibility test (rbl1), board was CHARGING after usbpull3
|