- LBC supervisor v1..v4 (linux/patches/b10b3-lbc-supervisor-v3.patch + b10/b10b3/lbc-v3-to-v4-fault-clamp.diff): CHARGING 4.20 V/450 mA -> HOLD 4.05 V after 60 min CV -> battery -> new cycle on USB insert; FAULT = VDD_MAX 4.00 V clamp - RAM tests C/B/D/D2/D3/D4 (safety timer only ends fast charge), B10B-4 actuator audit (VDD_MAX works, USB_SUSP does not), B10B-5 FAULT clamp regression, production run, warm reboot via PON reboot reason - cache = B10B-5 c3732515 (HW EDL write, readback + full partition verify), class-A persistent validation - test-only hooks/images are not part of the production kernel; images with the AP PSK are not published
24 lines
828 B
Text
24 lines
828 B
Text
// SPDX-License-Identifier: GPL-2.0-only
|
|
/*
|
|
* Project Aurora - B10B-1 (RAM test only) = B10B-0 DTB + simple-battery + upstream PM8916 VM-BMS (pm8916_bms).
|
|
* pm8916_charger (LBC) stays disabled, pm8916_usbin unchanged.
|
|
* Battery values are temporary for B10: capacity 3000 mAh, min 3.4 V. voltage-max-design is deliberately capped at 4.20 V
|
|
* although the cell allows 4.35 V. simple-battery has no nominal-voltage property, so 3.8 V nominal is not expressed here.
|
|
*/
|
|
#include "msm8916-jz08-aurora-b10b0.dts"
|
|
|
|
/ {
|
|
model = "JZ08AU Aurora (RAM boot B10B-1)";
|
|
|
|
battery: battery {
|
|
compatible = "simple-battery";
|
|
charge-full-design-microamp-hours = <3000000>;
|
|
voltage-min-design-microvolt = <3400000>;
|
|
voltage-max-design-microvolt = <4200000>;
|
|
};
|
|
};
|
|
|
|
&pm8916_bms {
|
|
status = "okay";
|
|
monitored-battery = <&battery>;
|
|
};
|